<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Asset deployment | Treon Knowledgebase</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/</link><atom:link href="https://kb.treon.fi/industrialnodex/assetdeployment/index.xml" rel="self" type="application/rss+xml"/><description>Asset deployment</description><generator>Wowchemy (https://wowchemy.com)</generator><language>en-us</language><copyright>© Treon 2026</copyright><image><url>https://kb.treon.fi/images/logo_hu94445a51fdceac9802ef138cdfec2a70_6567_300x300_fit_lanczos_2.png</url><title>Asset deployment</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/</link></image><item><title>Treon Industrial Node X deployment strategy</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodexdeployment/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodexdeployment/</guid><description>&lt;p>Deploying the Treon Industrial Node X in an industrial environment is straightforward, but multiple factors need to be taken into consideration:&lt;/p>
&lt;ul>
&lt;li>the installation location on the monitored asset.&lt;/li>
&lt;li>the mounting methods.&lt;/li>
&lt;li>surface and environmental temperatures.&lt;/li>
&lt;li>hazardous areas.&lt;/li>
&lt;li>the layout of the whole mesh network.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;h2 id="general-product-information">General product information&lt;/h2>
&lt;p>&lt;strong>Treon Industrial Node X&lt;/strong>&lt;/p>
&lt;ul>
&lt;li>Mounting interface: M30×2.0 adapter interface.&lt;/li>
&lt;li>30 mm direct mounting surface.&lt;/li>
&lt;li>Weight: 210g&lt;/li>
&lt;li>Environmental: IP6K9K rating.&lt;/li>
&lt;li>Temperature range: −40 to +85 °C operation temperature range.&lt;/li>
&lt;li>Sensing: tri‑axial vibration (usable up to ~6.3 kHz depending on mounting), surface temperature −40 to +85 °C.&lt;/li>
&lt;/ul>
&lt;p>For more information, please see the &lt;a href="https://kb.treon.fi/content/industrialnodex/nodex_datasheet">Treon Industrial Node X datasheet&lt;/a>.&lt;/p>
&lt;p> 
&lt;img src="https://kb.treon.fi/media/nodex/nodex_nodexdiag1.png" width="450">
 &lt;/p>
&lt;h2 id="installation-location">Installation location&lt;/h2>
&lt;p>The aim is to pick an installation location on the asset that has the best measurable vibration and temperature reading for permanent monitoring of the asset and predictive maintenance.&lt;/p>
&lt;p>As a general rule, mount the Treon Industrial Node X sensor as close to the bearing load zone as feasible.&lt;/p>
&lt;p>Avoid installation on thin covers or guards or loosely fastened parts that can resonate, such as for example motor fan cover. Also avoid areas where other machine parts or on-location personnel have a high chance of getting into contact with the sensor.&lt;/p>
&lt;p>Do not deploy the Treon Industrial Node X to high temperatures locations over 85 °C and any other locations that might lead to sub-optimal sensor readings, damage to the sensor, and reduced battery life-time.&lt;/p>
&lt;p>Always consult the assets' product documentation of the asset before installing a sensor.&lt;/p>
&lt;p>Read more about &lt;a href="https://kb.treon.fi/content/industrialnodex/assetdeployment/nodexlocations">choosing the best installation location&lt;/a>.&lt;br>
 &lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="mounting-method">Mounting method&lt;/h2>
&lt;p>There are five recommended mounting methods for the Treon Industrial Node X:&lt;/p>
&lt;ul>
&lt;li>Treon Bolt Mount Adapter mounting&lt;/li>
&lt;li>Treon Orientation Adapter mounting&lt;/li>
&lt;li>Treon Magnetic Glue Adapter for Flat Surface mounting&lt;/li>
&lt;li>Treon Magnetic Glue Adapter for Curved Surface mounting&lt;/li>
&lt;li>Direct glue mounting&lt;/li>
&lt;/ul>
&lt;p>Bolt mounting via the Treon Bolt Mount Adapter or the Treon Orientation Adapter are the most suitable solution for most assets.&lt;/p>
&lt;p>Read our full documentation on &lt;a href="https://kb.treon.fi/content/industrialnodex/assetdeployment/nodex_mounting_overview">mounting strategies for the Treon Industrial Node X&lt;/a>.&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="mesh-network-layout">Mesh network layout&lt;/h2>
&lt;p>When deploying your Treon solution, it is key to plan the Wirepas mesh network before the actual on-site installation.&lt;/p>
&lt;p>The layout of the deployment environment and location of monitored assets will define the best placement for gateways and design of the whole mesh network. It is essential to plan the whole mesh network layout before the actual deployment, so all data is delivered from the sensor nodes to the Treon Connect instance smoothly.&lt;/p>
&lt;p>Read our full article series on &lt;a href="https://kb.treon.fi/content/industrialnodex/meshdeployment/_index">Wirepas mesh network strategies for the Treon Industrial Node X&lt;/a>.&lt;/p>
&lt;p> 
 &lt;/p></description></item><item><title>Treon Industrial Node X installation location</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodexlocations/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodexlocations/</guid><description>&lt;h2 id="installation-location">Installation location&lt;/h2>
&lt;p>The aim is to pick an installation location on the asset that has the best measurable vibration and temperature reading for predictive maintenance of the asset.&lt;/p>
&lt;p>As a general rule, mount the Treon Industrial Node X as close to the bearing load zone as feasible.&lt;/p>
&lt;p>Avoid installation on thin covers or guards or loosely fastened parts that can resonate, such as for example motor fan cover. Also avoid areas where other machine parts or on-location personnel have a high chance of getting into contact with the sensor.&lt;/p>
&lt;p>Avoid placing the Treon Industrial Node X to high temperatures locations over 85 °C and any other locations that might lead to sub-optimal sensor readings,damage to the sensor, or reduced battery life-time.&lt;/p>
&lt;p>Always consult the product documentation of the asset before installing a sensor.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="horizontal-machines">Horizontal machines&lt;/h3>
&lt;p>For machines with &lt;strong>horizontal alignment or installation&lt;/strong> we propose the sensor locations depicted in the graphics below. In most cases, these will lead to optimal sensor readings on a horizontal machine.&lt;/p>
&lt;p>Please note that the bearing load zone is typically located on the bottom half of the bearing.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_horizontal1.png" width="250">
&lt;img src="https://kb.treon.fi/media/nodex/nodex_horizontal2.png" width="200">
&lt;p> &lt;/p>
&lt;h3 id="vertical-machines">Vertical machines&lt;/h3>
&lt;p>For machines with &lt;strong>vertical&lt;/strong> alignment or installation we propose the sensor locations depicted in the graphic below. In most cases, these will lead to optimal sensor readings on a vertical machine.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_vertical1.png" width="300">
&lt;p> &lt;/p>
&lt;h3 id="node-orientation-and-measurement-directions">Node orientation and measurement directions&lt;/h3>
&lt;p>Align all Treon Industrial Node X sensors on the asset and across assets in the same direction whenever possible. Unified orientation helps analyzing the measurements as readings from sensor axis are directly comparable.&lt;/p>
&lt;p>Align node axes as follows:&lt;br>
• Align one node axis to the assets horizontal direction&lt;br>
• Align one node axis to the assets vertical direction&lt;br>
• Align one node axis with the asset&amp;rsquo;s shaft direction&lt;/p>
&lt;p>As a visual reference, use the Treon Industrial Node X&amp;rsquo;s safety‑screw opening which represents the node&amp;rsquo;s Z-axis.&lt;/p>
&lt;p>Manual alignment of the node during installation requires a Treon Magnetic Glue Adapter for Flat Surface, Treon Magnetic Glue Adapter for Curved Surface or Treon Orientation Adapter. The Treon Bolt Mount Adapter does not allow axis rotation during installation or afterward.&lt;/p>
&lt;p>It is recommended to always use at least one radial (vertical or horizontal) direction. Axial measurements should be taken at least in axial load carrying (thrust) bearing locations.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_node2.png" width="140">
&lt;p> &lt;/p>
&lt;h3 id="mounting">Mounting&lt;/h3>
&lt;p>Prefer bolt mounting and spot face drilling for best frequency response. For bolt mounting orientation adapter is recommended so that Node can be oriented properly.&lt;/p>
&lt;p>Do not glue if there is a risk of damage to machinery in case the glue fails causing a sensor detachment.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="amount-of-nodes">Amount of Nodes&lt;/h3>
&lt;p>Preferably one Node per (key) bearing. If bearings are less than 25 cm (10 inch) apart, one sensor is sufficient to monitor both. This is valid for small motors, pumps, fans and gearboxes. &lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="good-mounting-practice">Good mounting practice&lt;/h2>
&lt;p>&lt;strong>Example 1&lt;/strong>: Ideal sensor orientation on a horizontal machine.&lt;/p>
&lt;p>The sensor node axes align with each other and to real world horizontal (Y), vertical (X) and axial (Z) directions. This helps when analyzing the data.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_mountingex1.png" width="450">
&lt;p> &lt;/p>
&lt;p>&lt;strong>Example 2&lt;/strong>: Measurement locations on a large motor and overhung fan unit.&lt;br>
One sensor node is installed close to each of the bearings (two on motor and two on fan bearings housings). The node orientations are aligned, which makes sensor data analysis easier and enables comparization of sensor data across multiple sensors.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_mountingex2.png" width="450">
&lt;p> &lt;/p>
&lt;p>&lt;strong>Example 3&lt;/strong>: Measurement locations on a large gearmotor.&lt;br>
Two sensor nodes are installed on the motor - one to the NDE (non-drive-end) and the other to the DE (drive-end). Two sensor are installed to gear - one near the input shaft and one near the output shaft.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_mountingex3.png" width="450">
&lt;p> &lt;/p>
&lt;p>&lt;strong>Example 4&lt;/strong>: Good measurement locations marked on a small gearmotor.&lt;br>
Two sensor nodes can be considered sufficient for this asset. One sensor is installed to the motor (DE (drive-end) usually offer better mounting surfaces than NDE (non-drive-end)) and one sensor is installed near the gear output shaft.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_mountingex4.png" width="450">
&lt;p> &lt;/p>
&lt;h2 id="improper-mounting-locations">Improper mounting locations&lt;/h2>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_mountingex5.png" width="400">
&lt;p>&lt;strong>Mistake 1&lt;/strong>: Motor cooler fan cover mounting.&lt;br>
Installation of the sensor node on the motor cooler fan cover will predominantly pick up cooler fan vibrations which are not useful for asset condition monitoring.&lt;/p>
&lt;p>&lt;strong>Mistake 2&lt;/strong>: Motor cooler fin mounting.&lt;br>
Installation of the sensor node on the motor cooler fin will predominantly pick up cooler fin vibrations which are not useful for asset condition monitoring.&lt;/p>
&lt;p>&lt;strong>Mistake 3&lt;/strong>: Machine base mounting.&lt;br>
Installation directly on the machine base will likely be too far from the source of vibrations and only pick up dampened and mixed-up vibrations from the whole asset and not the parts to be monitored.&lt;/p>
&lt;p>&lt;strong>Mistake 4&lt;/strong>: Shaft cover mounting.&lt;br>
Installation on the shaft cover will likely be too far from the source of vibrations and only pick up dampened and mixed-up vibrations from the whole asset and not the parts to be monitored.&lt;/p>
&lt;h2 id="troubleshooting">Troubleshooting&lt;/h2>
&lt;details> &lt;summary>Error: Cannot identify the best mounting location.&lt;/summary>Finding the ideal place to mount the Treon Industrial Node X to an asset might not be straight-forward and require some experience. &lt;br>
Carefully read our instructions above on choosing a location. Think which vibrations you want to measure for ideal monitoring of your asset. &lt;br>
If you are still unsure about the mounting location, consider a specialist's consultation with Treon.
&lt;/details>
&lt;details> &lt;summary>Error: Sensor data does not match previous data. &lt;/summary>
When another sensor previously installed on the asset delivered different vibration or temperature data, this can have a multitude of reasons. &lt;br>
First, check that the Treon Industrial Node X is mounted in a location that picks up sensor data in a similar quality than your previous sensor in order to make it comparable. &lt;br>
Make sure the method the Treon Industrial Node X has been mounted with has been executed correctly and is suitable for the sensor location on the asset. &lt;br>
Check if both sensors have been aligned on the asset in a comparable way, and if sensor data from the same axes of the asset are compared.
&lt;/details>
&lt;details> &lt;summary>Error: Sensor data does not match data from another sensor. &lt;/summary>
When another sensor currently installed on the asset delivers different vibration or temperature data, this can have a multitude of reasons. &lt;br>
Take into account that two sensors cannot be mounted in exactly the same location, so that there will always be a difference in the data.
First, check that the Treon Industrial Node X is mounted in a location that picks up sensor data in a similar quality than your other sensor in order to make it comparable. &lt;br>
Make sure the method the Treon Industrial Node X has been mounted with has been executed correctly and is suitable for the sensor location on the asset. &lt;br>
Check if both sensors have been aligned on the asset in a comparable way, and if sensor data from the same axes of the asset is compared.
&lt;/details>
&amp;nbsp;
&amp;nbsp;</description></item><item><title>Mounting strategies for Treon Industrial Node X</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_overview/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_overview/</guid><description>&lt;h2 id="introduction">Introduction&lt;/h2>
&lt;p>When mounting the Treon Industrial Node X to an asset, consider the location of the sensor and the contact between the sensor and the machine. The best location to attach the sensor depends on the machine and the monitored vibration source.&lt;/p>
&lt;p>For best measurement quality, the contact surface on the machine should be:&lt;/p>
&lt;ul>
&lt;li>&lt;strong>completely flat&lt;/strong>: within 0.03 mm (1 mil = 1/1000th inch)&lt;/li>
&lt;li>&lt;strong>smooth&lt;/strong>: surface texture no greater than Ra 0.8 (32 microinches)&lt;/li>
&lt;li>&lt;strong>larger than the base of the Treon Industrial Node X&lt;/strong>&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;h2 id="installation-methods">Installation methods&lt;/h2>
&lt;p>There are five recommended installation methods:&lt;/p>
&lt;ul>
&lt;li>Treon Bolt Mount Adapter&lt;/li>
&lt;li>Treon Orientation Adapter&lt;/li>
&lt;li>Treon Magnetic Glue Adapter for Flat Surface&lt;/li>
&lt;li>Treon Magnetic Glue Adapter for Curved Surface&lt;/li>
&lt;li>Direct glue mounting&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_installationmethods1.png" width="450">
&lt;table>
&lt;thead>
&lt;tr>
&lt;th>Mount type&lt;/th>
&lt;th>Bonding&lt;/th>
&lt;th>Minimum mounting surface diameter&lt;/th>
&lt;th>Minimum thread hole depth&lt;/th>
&lt;th>Curved surface&lt;/th>
&lt;th>Allows manual orientation&lt;/th>
&lt;th>Total height (node + adapter)&lt;/th>
&lt;/tr>
&lt;/thead>
&lt;tbody>
&lt;tr>
&lt;td>Treon Bolt Mount Adapter&lt;/td>
&lt;td>M6x1 or M8x1,25 bolt&lt;/td>
&lt;td>31,7 mm [1.25 in]&lt;/td>
&lt;td>9 mm [0.35 in]&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>88 mm [3.46 in]&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Treon Orientation Adapter&lt;/td>
&lt;td>M6x1 or M8x1,25 bolt&lt;/td>
&lt;td>25 mm [0.98 in]&lt;/td>
&lt;td>9 mm [0.35 in]&lt;/td>
&lt;td>No&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>91 mm [3.58 in]&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Treon Magnetic Glue Adapter for Flat Surface&lt;/td>
&lt;td>Glue&lt;/td>
&lt;td>31,7 mm [1.24 in]&lt;/td>
&lt;td>–&lt;/td>
&lt;td>No&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>89 mm [3.50 in]&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Treon Magnetic Glue Adapter for Curved Surface&lt;/td>
&lt;td>Glue&lt;/td>
&lt;td>33 mm [1.3 in]&lt;/td>
&lt;td>–&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>89 mm [3.50 in]&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Direct glue mounting&lt;/td>
&lt;td>Glue&lt;/td>
&lt;td>31,7 mm [1.25 in]&lt;/td>
&lt;td>–&lt;/td>
&lt;td>No&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>80 mm [3.15 in]&lt;/td>
&lt;/tr>
&lt;/tbody>
&lt;/table>
&lt;p> &lt;/p>
&lt;p>The four different adapters for Treon Industrial Node X have different installation surfaces:&lt;/p>
&lt;figure>&lt;img src="https://kb.treon.fi/media/nodex/nodex_installationmethods2.png" width="450">&lt;figcaption>Treon Bolt Mount Adapter, Treon Orientation Adapter, &lt;br>Treon Magnetic Glue Adapter for Flat Surface, Treon Magnetic Glue Adapter for Curved Surface&lt;/figcaption>&lt;/figure>
&lt;p> &lt;/p>
&lt;h2 id="choosing-the-right-installation-method">Choosing the right installation method&lt;/h2>
&lt;h1 id="installation-method-comparison-table">Installation Method Comparison Table&lt;/h1>
&lt;table>
&lt;thead>
&lt;tr>
&lt;th>&lt;strong>Installation Method&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Direct Glue Mounting&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Bolt Mount Adapter&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Orientation Adapter&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Magnetic Glue Mount Adapter (Flat Surface)&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Magnetic Glue Mount Adapter (Curved Surface)&lt;/strong>&lt;/th>
&lt;/tr>
&lt;/thead>
&lt;tbody>
&lt;tr>
&lt;td>&lt;strong>Bonding&lt;/strong>&lt;/td>
&lt;td>Glue&lt;/td>
&lt;td>M6×1 or M8×1.25 bolt&lt;/td>
&lt;td>M6×1 or M8×1.25 bolt&lt;/td>
&lt;td>Glue&lt;/td>
&lt;td>Glue&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Minimum mounting surface diameter&lt;/strong>&lt;/td>
&lt;td>31.7 mm (1.25 in)&lt;/td>
&lt;td>31.7 mm (1.25 in)&lt;/td>
&lt;td>25 mm (0.98 in)&lt;/td>
&lt;td>31.7 mm (1.24 in)&lt;/td>
&lt;td>33 mm (1.30 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Minimum thread hole depth&lt;/strong>&lt;/td>
&lt;td>–&lt;/td>
&lt;td>9 mm (0.35 in)&lt;/td>
&lt;td>9 mm (0.35 in)&lt;/td>
&lt;td>–&lt;/td>
&lt;td>–&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Total height (Node + adapter)&lt;/strong>&lt;/td>
&lt;td>80 mm (3.15 in)&lt;/td>
&lt;td>88 mm (3.46 in)&lt;/td>
&lt;td>91 mm (3.58 in)&lt;/td>
&lt;td>89 mm (3.50 in)&lt;/td>
&lt;td>89 mm (3.50 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Curved surface&lt;/strong>&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Uneven surface&lt;/strong>&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Allows manual orientation&lt;/strong>&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>No&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Frequency response (vibration)&lt;/strong>&lt;/td>
&lt;td>Excellent&lt;/td>
&lt;td>Excellent&lt;/td>
&lt;td>Good&lt;/td>
&lt;td>Good&lt;/td>
&lt;td>Good&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Temperature response (steady‑state)&lt;/strong>&lt;/td>
&lt;td>Excellent&lt;/td>
&lt;td>Good&lt;/td>
&lt;td>Good&lt;/td>
&lt;td>Medium&lt;/td>
&lt;td>Medium&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Fast temperature change response&lt;/strong>&lt;/td>
&lt;td>Excellent&lt;/td>
&lt;td>Good&lt;/td>
&lt;td>Good&lt;/td>
&lt;td>Medium&lt;/td>
&lt;td>Medium&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>&lt;strong>Affects magnetometer measurements&lt;/strong>&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>No&lt;/td>
&lt;td>Yes&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;/tbody>
&lt;/table>
&lt;p> &lt;/p>
&lt;h2 id="surface-preparation">Surface preparation&lt;/h2>
&lt;p>For a proper and long-lasting installation of the Treon Industrial Node X, it is essential that the installation surface is as flat, smooth and clean as possible.&lt;/p>
&lt;p>Ensure the machine contact surface is as flat as possible. Whenever it is possible to smoothen the installation surface, smoothen a surface larger than the base of the Treon Industrial Node X to ensure optimal mounting.&lt;/p>
&lt;p>In case it is not possible to smoothen the installation surface, choose an installation method that will enable best possible sensor readings.&lt;/p>
&lt;p>In case the mounting surface is covered by paint, consider removing the paint before installation of the sensor if possible.&lt;/p>
&lt;p>Before installation of the Treon Industrial Node X, clean the surface to remove all dirt, grease and other contaminants.&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="alignment">Alignment&lt;/h2>
&lt;p>For accurate interpretation of the measurement data of all sensor axis, the centerline of Treon Industrial Node X is often aligned with the shaft of the rotating machine. This can be done by manually aligning the sensor with the shaft.&lt;/p>
&lt;p>Manual alignment requires using the Treon Orientation Adapter or direct gluing. When mounting the sensor, align its axis directly toward drive or non- drive end of monitored machine using the orientation notch in the top window and the safety screw opening as visual guidelines&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_alignment1.png" width="500">
&lt;p> &lt;/p>
&lt;h3 id="installation-with-treon-bolt-mount-adapterconnectindustrialnodexassetdeploymentnodex_installation_method1">&lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method1">Installation with Treon Bolt Mount Adapter&lt;/a>&lt;/h3>
&lt;p>The Treon Industrial Bolt Mount Adapter is directly attached to the asset&amp;rsquo;s surface. This minimizes the vibration transmission route for best measurement quality. Manual alignment of the Treon Industrial Node is not possible with this installation method.&lt;/p>
&lt;p>Installation with Treon Bolt Mount Adapter requires a flat surface of 31.7 mm or 1.25 in diameter, and a hole for an M6x1 or M8x1,25 bolt with 9 mm or 0.35 in depth of threading.&lt;/p>
&lt;p>Read the &lt;a href="https://kb.treon.fi/connect/module2/assetinstallation/indnode_installation_method1">full article on installation without an adapter here.&lt;/a>&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_adapt_bolt1.png" width="140">
&amp;nbsp;
&lt;h3 id="installation-with-treon-orientation-adapterconnectindustrialnodexassetdeploymentnodex_installation_method2">&lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method2">Installation with Treon Orientation Adapter&lt;/a>&lt;/h3>
&lt;p>Using a Treon Orientation Adapter has the benefits of the Treon Bolt Adapter with the additional benefit that it allows manual orientation of the Treon Industrial Node X during installation.&lt;/p>
&lt;p>Installation with a Treon Orientation Adapter requires a flat surface of 25 mm or 0.98 in diameter, and a hole for an M6x1 or M8x1,25 bolt with 9 mm or 0.35 in depth of threading.&lt;/p>
&lt;p>Read the &lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method2">full article on installation with a Treon Orientation Adapter here.&lt;/a>&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_adapt_orient1.png" width="140">
&amp;nbsp;
&lt;h3 id="treon-magnetic-glue-adapter-for-flat-surfaceconnectindustrialnodexassetdeploymentnodex_installation_method3">&lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method3">Treon Magnetic Glue Adapter for Flat Surface&lt;/a>&lt;/h3>
&lt;p>Using the Treon Magnetic Glue Adapter for Flat Surface enables attaching the Treon Industrial Node to flat surfaces without drilling a hole for a bolt. It is possible to manually align the Treon Magnetic Glue Adapter for Flat Surface.&lt;/p>
&lt;p>Installation with a Treon Magnetic Glue Adapter for Flat Surface requires a Treon Magnetic Glue Adapter for Flat Surface, suitable glue, and a surface area of minimum 31.7 mm or 1.24 in diameter.&lt;/p>
&lt;p>Read the &lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method3">full article on installation with a Treon Magnetic Glue Adapter for Flat Surface here.&lt;/a>&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_adapt_glueflat1.png" width="140">
&amp;nbsp;
&lt;h3 id="treon-magnetic-glue-adapter-for-curved-surfaceconnectindustrialnodexassetdeploymentnodex_installation_method4">&lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method4">Treon Magnetic Glue Adapter for Curved Surface&lt;/a>&lt;/h3>
&lt;p>Using the Treon Magnetic Glue Adapter for Curved Surface enables attaching the Treon Industrial Node to curved surfaces without drilling a hole for a bolt. It is possible to manually align the Treon Magnetic Glue Adapter for Curved Surface.&lt;/p>
&lt;p>Installation with a Treon Magnetic Glue Adapter for Curved Surface requires a Treon Magnetic Glue Adapter for Curved Surface, suitable glue, and a surface area of at least 33 mm or 1.3 in diameter.&lt;/p>
&lt;p>Read the &lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method4">full article on Installation with a Treon Magnetic Glue Adapter for Curved Surface here.&lt;/a>&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_adapt_gluecurved1.png" width="140">
&amp;nbsp;
&lt;h3 id="direct-glue-mountingconnectindustrialnodexassetdeploymentnodex_installation_method5">&lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method5">Direct glue mounting&lt;/a>&lt;/h3>
&lt;p>Direct glue mounting allows installation of the Treon Industrial Node X to any flat or slightly uneven surfact directly without the use of an adapter.&lt;/p>
&lt;p>Direct glue mounting requires suitable glue, and a surface area of at least 31.7 mm or 1.25 in diameter.&lt;/p>
&lt;p>Read the &lt;a href="https://kb.treon.fi/connect/industrialnodex/assetdeployment/nodex_installation_method5">full article on Direct glue mounting here.&lt;/a>&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="improper-mounting-techniques">Improper mounting techniques&lt;/h2>
&lt;p>&lt;strong>Mistake 1&lt;/strong>: Wrong mounting location&lt;br>
Mounting should happen directly to the asset, not on parts extruding from the asset such as fan covers and cooling fins.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_mountingex6.png" width="140">
&lt;p> &lt;/p>
&lt;p>&lt;strong>Mistake 2&lt;/strong>: Uneven mounting base&lt;br>
Mounting should happen on an even surface, with the Treon Industrial Node X mounted on a 90° angle to the surface.&lt;/p>
&lt;p>&amp;lt;imgsrc=&amp;quot;/media/nodex/nodex_mountingex7.png&amp;quot; width=&amp;ldquo;180&amp;rdquo;&amp;gt;&lt;/p>
&lt;p> &lt;/p>
&lt;p>&lt;strong>Mistake 3&lt;/strong>: Bolt-mounting without adapter&lt;br>
When you install the Treon Industrial Node X on the asset via a drill hole, make sure you use the right adapter:&lt;/p>
&lt;ul>
&lt;li>Treon Bolt Mount Adapter or&lt;/li>
&lt;li>Treon Orientation Adapter.&lt;/li>
&lt;/ul>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_mountingex8.png" width="160">
&lt;p> 
 &lt;/p></description></item><item><title>Installation with Treon Bolt Mount Adapter</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method1/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method1/</guid><description>&lt;h2 id="introduction---treon-bolt-mount-adapter">Introduction - Treon Bolt Mount Adapter&lt;/h2>
&lt;p>With the Treon Bolt Mount Adapter, the Treon Industrial Node X is directly attached to the machine surface. This minimizes the vibration transmission route for best measurement quality. Manual alignment of the Industrial Node X is not possible with this installation method.&lt;/p>
&lt;p>This installation method requires a flat surface of at least 31.7 mm or 1.25 in diameter, and a hole for an M6×1 or M8×1.25 bolt with at least 9 mm or 0.35 in depth of threading.&lt;/p>
&lt;p>&lt;strong>Applies to:&lt;/strong> Treon Industrial Node X&lt;br>
&lt;strong>Adapter:&lt;/strong> Treon Bolt Mount Adapter&lt;br>
&lt;strong>Use when:&lt;/strong> You can tap/drill a mounting hole on a completely flat, smooth surface and manual alignment is not necessary.&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="specifications">Specifications&lt;/h2>
&lt;table>
&lt;thead>
&lt;tr>
&lt;th>&lt;strong>Parameter&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Value&lt;/strong>&lt;/th>
&lt;/tr>
&lt;/thead>
&lt;tbody>
&lt;tr>
&lt;td>Bonding&lt;/td>
&lt;td>M6×1 or M8×1.25 bolt&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum mounting surface diameter&lt;/td>
&lt;td>31.7 mm (1.25 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum thread hole depth&lt;/td>
&lt;td>9 mm (0.35 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Total height (Node + adapter)&lt;/td>
&lt;td>88 mm (3.46 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Curved surface&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Uneven surface&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Allows manual orientation&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Frequency response (vibration)&lt;/td>
&lt;td>Excellent&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Temperature response (steady‑state)&lt;/td>
&lt;td>Good&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Fast temperature change response&lt;/td>
&lt;td>Good&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Affects magnetometer measurements&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;/tbody>
&lt;/table>
&lt;p> &lt;/p>
&lt;h2 id="requirements">Requirements&lt;/h2>
&lt;p>For this installation method you will need:&lt;/p>
&lt;ul>
&lt;li>Treon Industrial Node X.&lt;/li>
&lt;li>Treon Bolt Mount Adapter.&lt;/li>
&lt;li>Tap/drill M6×1 or M8×1.25 bolt of minimum 9 mm or 0.35 in depth.&lt;/li>
&lt;li>Torque wrench capable of applying 20 Nm.&lt;/li>
&lt;li>Cleaning materials (degreaser/isopropyl alcohol, lint‑free wipes).&lt;/li>
&lt;li>Personal protective equipment (PPE) as per site rules.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;h2 id="safety--preparation">Safety &amp;amp; Preparation&lt;/h2>
&lt;ol>
&lt;li>Isolate an/or turn off the asset and other equipment in close proximity if required by your site procedures.&lt;/li>
&lt;li>Select a flat, smooth area larger than the sensor base close to the measurement point and away from resonant/loose parts.&lt;/li>
&lt;li>Clean the surface thoroughly; remove paint, rust, oil, and debris.&lt;/li>
&lt;li>Verify there is sufficient thickness in the asset&amp;rsquo;s material for the tapped hole.&lt;/li>
&lt;/ol>
&lt;p> &lt;/p>
&lt;h2 id="step-by-step-installation-guide">Step-by-step installation guide&lt;/h2>
&lt;h3 id="step-1-drill-mounting-hole">Step 1: Drill mounting hole&lt;/h3>
&lt;p>Start with carefully drilling an M6×1 or M8×1.25 hole into the machine surface at the location you have chosen for the measurements. Please consider carefully where you drill the hole. If you are unsure, please consult the manual of the machine or the manufacturer.&lt;/p>
&lt;p>Be sure to drill the hole with the correct alignment to the machine. For most uses, an exact angle of 90° to the plane will be the right choice.&lt;/p>
&lt;p>The minimum required thread hole depth to drill is 9 mm or 0.35 in.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="step-2-clean-the-surface">Step 2: Clean the surface&lt;/h3>
&lt;p>After drilling, clean the machine surface thoroughly.&lt;/p>
&lt;!-- Greasing??Then apply silicon grease and spread it with your finger in an unpowdered latex glove as shown in the pictures -->
&lt;!--
&lt;table>
&lt;tr>
&lt;th>&lt;figure>&lt;img src="https://kb.treon.fi/media/indnode_inst_meth1_1.png" width="250">&lt;figcaption>Fig.: Clean the surface&lt;/figcaption>&lt;/figure>
&lt;/th>
&lt;th>&lt;figure>&lt;img src="https://kb.treon.fi/media/indnode_inst_meth1_2.png" width="250">&lt;figcaption>Fig.: Apply the grease&lt;/figcaption>&lt;/figure>&lt;/th>
&lt;th>&lt;figure>&lt;img src="https://kb.treon.fi/media/indnode_inst_meth1_3.png" width="250">&lt;figcaption>Fig.: Spread the grease&lt;/figcaption>&lt;/figure>&lt;/th>
&lt;/tr>
&lt;/table>
-->
&lt;p> &lt;/p>
&lt;h3 id="step-3-attach-mounting-bolt-to-adapter">Step 3: Attach mounting bolt to adapter&lt;/h3>
&lt;p>Attach the mounting bolt to the Treon Bolt Adapter by carefully screwing it in with a screwdriver. Choose the M6×1 bolt if you drilled an M6 hole and the M8×1.25 bolt if you drilled an M8 hole.&lt;/p>
&lt;p>&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130148.jpg" width="300">&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130154.jpg" width="300">&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="step-4-tighten-adapter-to-node">Step 4: Tighten adapter to node&lt;/h3>
&lt;p>Place the Treon Bolt Adapter with the attached mounting bolt on the Treon Industrial Node X and carefully screw it in.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130207.jpg" width="300">
Use a socket wrenches to tighten the connection.
&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130306.jpg" width="300">&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130330.jpg" width="300">
&lt;p> &lt;/p>
&lt;h3 id="step-5-attach-to-machinery">Step 5: Attach to machinery&lt;/h3>
&lt;p>Now screw the Treon Industrial Node X with attached Treon Bolt Adapter into the M6 or M8 hole on the asset&amp;rsquo;s surface.&lt;/p>
&lt;p>Optionally a threadlocker can be used if needed to secure the device in place.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="step-6-tighten">Step 6: Tighten&lt;/h3>
&lt;p>Now set your torque wrench with a spanner size of 34 mm to a tightness of 20 Nm (Newton metres) and carefully tighten the Treon Industrial Node X to the machine.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="verification">Verification&lt;/h3>
&lt;ul>
&lt;li>Confirm axis alignment marks match the intended directions.&lt;/li>
&lt;li>Run a quick measurement and validate expected directional sensitivity.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;p>&lt;strong>The Treon Industrial Node X is now fully installed!&lt;/strong>&lt;/p>
&lt;p> 
 &lt;/p>
&lt;h2 id="troubleshooting">Troubleshooting&lt;/h2>
&lt;details> &lt;summary>Error: The surface has paint.&lt;/summary>
If possible, remove all paint from the asset's surface. Make sure to consult the asset manufacturer's manual or contact the manufacturer directly if unsure.
&lt;/details>
&lt;details> &lt;summary>Error: The asset cannot be turned off.&lt;/summary>
In case the asset cannot be turned off for installation of the Treon Industrial Node X, please proceed with caution and take all safety protocols at the deployment site into account.
&lt;/details>
&lt;details> &lt;summary>Error: Cannot drill hole&lt;/summary>
In case it is not possible to drill an M6 or M8 hole with 9mm depth, please choose another installation method.
&lt;/details>
&lt;details> &lt;summary>Error: I over tightened the node.&lt;/summary>
Cannot be overtightened?
&lt;/details>
&lt;details> &lt;summary>Error: The asset was damaged.&lt;/summary>
If at any point it seems like the asset was damaged during the installation process, please consult the machine's repair manual or contact the manufacturer for further instructions on how to conduct the repair.
&lt;/details>
&amp;nbsp;
&amp;nbsp;
&lt;h2 id="disclaimer">Disclaimer&lt;/h2>
&lt;p>Treon is not responsible for any damage, injury, or malfunction resulting from the installation or use of the Treon Industrial Node X.&lt;/p>
&lt;p>Installation must be performed by qualified personnel.&lt;/p>
&lt;p>Any issues arising from incorrect installation, improper handling, or use outside the specified guidelines are the sole responsibility of the installer or end user.&lt;/p>
&lt;p> 
 &lt;/p></description></item><item><title>Installation with Treon Orientation Adapter</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method2/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method2/</guid><description>&lt;h2 id="introduction">Introduction&lt;/h2>
&lt;p>With the Orientation Adapter, the Treon Industrial Node X is attached to the machine surface using a threaded mounting hole. The adapter enables manual alignment, allowing the measurement axes to be oriented as needed for the monitored equipment.&lt;/p>
&lt;p>This installation method requires a flat surface of at least &lt;strong>25 mm (0.98 in)&lt;/strong> in diameter, and a threaded hole for an &lt;strong>M6×1 or M8×1.25&lt;/strong> bolt with a minimum depth of &lt;strong>9 mm (0.35 in)&lt;/strong>. For best measurement performance, the adapter should be tightened to approximately 20 Nm to ensure firm mechanical coupling.&lt;/p>
&lt;p>&lt;strong>Applies to:&lt;/strong> Treon Industrial Node X&lt;br>
&lt;strong>Adapter:&lt;/strong> Treon Orientation Adapter&lt;br>
&lt;strong>Use when:&lt;/strong> You need to align the measurement axes and have a threaded mounting hole on a flat surface.&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="specifications">Specifications&lt;/h2>
&lt;table>
&lt;thead>
&lt;tr>
&lt;th>&lt;strong>Parameter&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Value&lt;/strong>&lt;/th>
&lt;/tr>
&lt;/thead>
&lt;tbody>
&lt;tr>
&lt;td>Bonding&lt;/td>
&lt;td>M6×1 or M8×1.25 bolt&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum mounting surface diameter&lt;/td>
&lt;td>25 mm (0.98 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum thread hole depth&lt;/td>
&lt;td>9 mm (0.35 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Total height (Node + adapter)&lt;/td>
&lt;td>91 mm (3.58 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Curved surface&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Uneven surface&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Allows manual orientation&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Frequency response (vibration)&lt;/td>
&lt;td>Good&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Temperature response (steady‑state)&lt;/td>
&lt;td>Good&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Fast temperature change response&lt;/td>
&lt;td>Good&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Affects magnetometer measurements&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;/tbody>
&lt;/table>
&lt;p> &lt;/p>
&lt;h2 id="requirements">Requirements&lt;/h2>
&lt;p>For this installation method you will need:&lt;/p>
&lt;ul>
&lt;li>Treon Industrial Node X.&lt;/li>
&lt;li>Treon Orientation Adapter.&lt;/li>
&lt;li>Tap/drill M6×1 or M8×1.25 bolt hole with minimum 9 mm (0.35 in) thread depth.&lt;/li>
&lt;li>Torque wrench capable of applying 20 Nm.&lt;/li>
&lt;li>Cleaning materials (degreaser/isopropyl alcohol, lint‑free wipes).&lt;/li>
&lt;li>Personal protective equipment (PPE) as per site rules.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;h2 id="safety--preparation">Safety &amp;amp; Preparation&lt;/h2>
&lt;ol>
&lt;li>Isolate an/or turn off the asset and other equipment in close proximity if required by your site procedures.&lt;/li>
&lt;li>Select a flat, smooth area larger than the sensor base close to the measurement point and away from resonant/loose parts.&lt;/li>
&lt;li>Clean the surface thoroughly; remove paint, rust, oil, and debris.&lt;/li>
&lt;li>Verify there is sufficient thickness in the asset&amp;rsquo;s material for the tapped hole.&lt;/li>
&lt;/ol>
&lt;p> &lt;/p>
&lt;h2 id="step-by-step-installation-guide">Step-by-step installation guide&lt;/h2>
&lt;h3 id="step-1-drill-mounting-hole">Step 1: Drill mounting hole&lt;/h3>
&lt;p>Start with carefully drilling an M6×1 or M8×1.25 hole into the machine surface at the location you have chosen for the measurements. Please consider carefully where you drill the hole. If you are unsure, please consult the manual of the machine or the manufacturer.&lt;/p>
&lt;p>Be sure to drill the hole with the correct alignment to the machine. For most uses, an exact angle of 90° to the plane will be the right choice.&lt;/p>
&lt;p>The minimum required thread hole depth to drill is 9 mm or 0.35 in.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="step-2-clean-the-surface">Step 2: Clean the surface&lt;/h3>
&lt;p>After drilling, clean the machine surface thoroughly.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="step-3-attach-mounting-bolt-to-adapter">Step 3: Attach mounting bolt to adapter&lt;/h3>
&lt;p>Attach the mounting bolt to the Treon Bolt Adapter. Choose the M6×1 bolt if you drilled an M6 hole and the M8×1.25 bolt if you drilled an M8 hole.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130415.jpg" width="300">
&lt;p>Place hex key to hex socket on the top side of the adapter and tighten bolt wit a screwdriver.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130442.jpg" width="300">
&lt;p> &lt;/p>
&lt;h2 id="step-4-attach-orientation-adapter-to-orientation-nut">Step 4: Attach orientation adapter to orientation nut&lt;/h2>
&lt;p>Slide the orientation adapter to the orientation nut.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="step-5-mount-adapter-on-asset">Step 5: Mount adapter on asset&lt;/h3>
&lt;p>Place the assembly on the mounting hole on your asset. Tighten firmly with a hex key.&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="step-6-attach-adapter-to-asset">Step 6: Attach adapter to asset&lt;/h3>
&lt;p>Now install the Treon Orientation Adapter in the bolt hole on the cleaned asset&amp;rsquo;s surface.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130549.jpg" width="300">
&lt;p> &lt;/p>
&lt;h3 id="step-7-install-node-on-adapter">Step 7: Install node on adapter&lt;/h3>
&lt;p>Place the Treon Industrial Node X on the mounted adapter. Screw nut to the Node X but do not tighten.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130631.jpg" width="300">
&lt;p> &lt;/p>
&lt;h3 id="step-8-alignment">Step 8: Alignment&lt;/h3>
&lt;p>Rotate the node to desired orientation to align the axes.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_alignment1.png" width="450">
&lt;p>Tighten the connection with a spanner size 34 mm and a torque wrench set to exactly 20 Nm.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_130634.jpg" width="300">
&lt;p> &lt;/p>
&lt;h3 id="verification">Verification&lt;/h3>
&lt;ul>
&lt;li>Confirm axis alignment marks match the intended directions.&lt;/li>
&lt;li>Run a quick measurement and validate expected directional sensitivity.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;p>&lt;strong>The Treon Industrial Node X is now fully installed!&lt;/strong>&lt;/p>
&lt;p> 
 &lt;/p>
&lt;h2 id="troubleshooting">Troubleshooting&lt;/h2>
&lt;details> &lt;summary>Error: The surface has paint.&lt;/summary>
If possible, remove all paint from the asset's surface. Make sure to consult the asset manufacturer's manual or contact the manufacturer directly if unsure.
&lt;/details>
&lt;details> &lt;summary>Error: The asset cannot be turned off.&lt;/summary>
In case the asset cannot be turned off for installation of the Treon Industrial Node X, please proceed with caution and take all safety protocols at the deployment site into account.
&lt;/details>
&lt;details> &lt;summary>Error: Cannot drill hole&lt;/summary>
In case it is not possible to drill an M6 or M8 hole with 9mm depth, please choose another installation method.
&lt;/details>
&lt;details> &lt;summary>Error: I over tightened the node.&lt;/summary>
Cannot be overtightened?
&lt;/details>
&lt;details> &lt;summary>Error: The asset was damaged.&lt;/summary>
If at any point it seems like the asset was damaged during the installation process, please consult the machine's repair manual or contact the manufacturer for further instructions on how to conduct the repair.
&lt;/details>
&amp;nbsp;
&amp;nbsp;
&lt;h2 id="disclaimer">Disclaimer&lt;/h2>
&lt;p>Treon is not responsible for any damage, injury, or malfunction resulting from the installation or use of the Treon Industrial Node X.&lt;/p>
&lt;p>Installation must be performed by qualified personnel.&lt;/p>
&lt;p>Any issues arising from incorrect installation, improper handling, or use outside the specified guidelines are the sole responsibility of the installer or end user.&lt;/p>
&lt;p> 
 &lt;/p></description></item><item><title>Installation with Treon Magnetic Glue Adapter for Flat Surface</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method3/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method3/</guid><description>&lt;h2 id="introduction">Introduction&lt;/h2>
&lt;p>With the Treon Magnetic Glue Mount Adapter for Flat Surface, the Treon Industrial Node X is glued to the equipment while the magnet temporarily holds the sensor in place during adhesive curing. This enables easy positioning and manual orientation prior to final bonding. After curing, the magnet is not responsible for holding the sensor in operation.&lt;/p>
&lt;p>This installation method requires a flat, smooth surface with a minimum diameter of &lt;strong>31.7 mm (1.24 in)&lt;/strong>. Magnetic adapters should not be used when measuring magnetic fields, as the magnet may interfere with the readings. Magnets are intended only as temporary support during installation.&lt;/p>
&lt;p>&lt;strong>Applies to:&lt;/strong> Treon Industrial Node X&lt;br>
&lt;strong>Adapter:&lt;/strong> Treon Magnetic Glue Mount Adapter for Flat Surface&lt;br>
&lt;strong>Use when:&lt;/strong> You need manual orientation and easy placement on a flat surface without drilling.&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="specifications">Specifications&lt;/h2>
&lt;table>
&lt;thead>
&lt;tr>
&lt;th>&lt;strong>Parameter&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Value&lt;/strong>&lt;/th>
&lt;/tr>
&lt;/thead>
&lt;tbody>
&lt;tr>
&lt;td>Bonding&lt;/td>
&lt;td>Glue&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum mounting surface diameter&lt;/td>
&lt;td>31.7 mm (1.24 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum thread hole depth&lt;/td>
&lt;td>–&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Total height (Node + adapter)&lt;/td>
&lt;td>89 mm (3.50 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Curved surface&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Uneven surface&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Allows manual orientation&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Frequency response (vibration)&lt;/td>
&lt;td>Good&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Temperature response (steady‑state)&lt;/td>
&lt;td>Medium&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Fast temperature change response&lt;/td>
&lt;td>Medium&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Affects magnetometer measurements&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;/tbody>
&lt;/table>
&lt;p> &lt;/p>
&lt;h2 id="requirements">Requirements&lt;/h2>
&lt;p>For this installation method you will need:&lt;/p>
&lt;ul>
&lt;li>Treon Industrial Node X.&lt;/li>
&lt;li>Treon Magnetic Glue Mount Adapter for Flat Surface.&lt;/li>
&lt;li>Flat mounting surface of at least 31.7 mm (1.24 in) diameter.&lt;/li>
&lt;li>Industrial‑grade glue or epoxy suitable for metal bonding.&lt;/li>
&lt;li>Cleaning materials (degreaser/isopropyl alcohol, lint‑free wipes).&lt;/li>
&lt;li>Personal protective equipment (PPE) as per site rules.&lt;/li>
&lt;/ul>
&lt;p>&lt;strong>Note&lt;/strong>: Magnets only hold the adapter during curing—final fixation depends on glue.&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="step-by-step-installation-guide">Step-by-step installation guide&lt;/h2>
&lt;p> &lt;/p>
&lt;h3 id="step-1-clean-the-surface">Step 1: Clean the surface&lt;/h3>
&lt;p>Clean the mounting surface on the asset thoroughly.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture3.png" width="200">
&lt;p> &lt;/p>
&lt;h3 id="step-2-attach-adapter-to-node">Step 2: Attach adapter to node&lt;/h3>
&lt;p>Take the Treon Magnetic Glue Mount Adapter for Flat Surface, place it on the Treon Industrial Node X. Carefully screw the adapter on to the node.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture1.png" width="150">
&lt;p>Tighten the connection with a spanner size 34 mm and a torque wrench to 20 Nm.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture2.png" width="200">
&lt;p> &lt;/p>
&lt;h3 id="step-3-apply-glue-to-surface">Step 3: Apply glue to surface&lt;/h3>
&lt;p>Choose an appropriate glue like the Loctite HY 4090. Follow closely the instructions that come with the glue!&lt;/p>
&lt;p>Apply the glue to the mounting area on the asset. The mounting area needs to be a minumum of 31.7 mm (1.24 in) in diameter.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture4.png" width="200">
&amp;nbsp;
&lt;h3 id="step-4-place-node-on-asset">Step 4: Place node on asset&lt;/h3>
&lt;p>Place the Treon Industrial Node X in the desired orientation on the area where you applied the glue. Make sure the magnet holds the node in place to secure the glue adhesion. Wait for the glue to dry.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture5.png" width="200">
&amp;nbsp;
&lt;h3 id="verification">Verification&lt;/h3>
&lt;ul>
&lt;li>Confirm axis alignment marks match the intended directions.&lt;/li>
&lt;li>Run a quick measurement and validate expected directional sensitivity.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;p>&lt;strong>The Treon Industrial Node X is now fully installed!&lt;/strong>&lt;/p>
&lt;p> 
 &lt;/p>
&lt;h2 id="troubleshooting">Troubleshooting&lt;/h2>
&lt;details> &lt;summary>Error: The surface has paint.&lt;/summary>
If possible, remove all paint from the asset's surface. Make sure to consult the asset manufacturer's manual or contact the manufacturer directly if unsure.
&lt;/details>
&lt;details> &lt;summary>Error: The asset cannot be turned off.&lt;/summary>
In case the asset cannot be turned off for installation of the Treon Industrial Node X, please proceed with caution and take all safety protocols at the deployment site into account.
&lt;/details>
&lt;details> &lt;summary>Error: Glue does not dry or hold.&lt;/summary>
Choose an appropriate glue such as the Loctite HY 4090 and follow closely the instructions that come with the glue.
&lt;/details>
&lt;details> &lt;summary>Error: The asset was damaged.&lt;/summary>
If at any point it seems like the asset was damaged during the installation process, please consult the machine's repair manual or contact the manufacturer for further instructions on how to conduct the repair.
&lt;/details>
&amp;nbsp;
&amp;nbsp;
&lt;h2 id="disclaimer">Disclaimer&lt;/h2>
&lt;p>Treon is not responsible for any damage, injury, or malfunction resulting from the installation or use of the Treon Industrial Node X.&lt;/p>
&lt;p>Installation must be performed by qualified personnel.&lt;/p>
&lt;p>Any issues arising from incorrect installation, improper handling, or use outside the specified guidelines are the sole responsibility of the installer or end user.&lt;/p>
&lt;p> 
 &lt;/p></description></item><item><title>Installation with Treon Magnetic Glue Adapter for Curved Surface</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method4/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method4/</guid><description>&lt;h2 id="introduction">Introduction&lt;/h2>
&lt;p>With the Treon Magnetic Glue Mount Adapter for Curved Surface, the Treon Industrial Node X can be installed on slightly curved or uneven mounting surfaces. The adapter compensates for curvature and allows the node to be correctly positioned and manually oriented before the adhesive cures. The magnet temporarily supports the sensor during curing but is not intended for long‑term retention.&lt;/p>
&lt;p>This installation method requires a curved mounting area of at least &lt;strong>33 mm (1.30 in)&lt;/strong> diameter. Magnetic adapters should not be used when measuring magnetic fields, because the magnet can interfere with the sensor’s magnetometer.&lt;/p>
&lt;p>&lt;strong>Applies to:&lt;/strong> Treon Industrial Node X&lt;br>
&lt;strong>Adapter:&lt;/strong> Treon Magnetic Glue Mount Adapter for Curved Surface
&lt;strong>Use when:&lt;/strong> The surface is curved or slightly uneven, drilling is not possible, and manual orientation is required.&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="specifications">Specifications&lt;/h2>
&lt;table>
&lt;thead>
&lt;tr>
&lt;th>&lt;strong>Parameter&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Value&lt;/strong>&lt;/th>
&lt;/tr>
&lt;/thead>
&lt;tbody>
&lt;tr>
&lt;td>Bonding&lt;/td>
&lt;td>Glue&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum mounting surface diameter&lt;/td>
&lt;td>33 mm (1.30 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum thread hole depth&lt;/td>
&lt;td>–&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Total height (Node + adapter)&lt;/td>
&lt;td>89 mm (3.50 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Curved surface&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Uneven surface&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Allows manual orientation&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Frequency response (vibration)&lt;/td>
&lt;td>Good&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Temperature response (steady‑state)&lt;/td>
&lt;td>Medium&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Fast temperature change response&lt;/td>
&lt;td>Medium&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Affects magnetometer measurements&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;/tbody>
&lt;/table>
&lt;p> &lt;/p>
&lt;h2 id="requirements">Requirements&lt;/h2>
&lt;p>For this installation method you will need:&lt;/p>
&lt;ul>
&lt;li>Treon Industrial Node X.&lt;/li>
&lt;li>Treon Magnetic Glue Mount Adapter for Curved Surface.&lt;/li>
&lt;li>Slightly curved mounting surface of at least 33 mm (1.30 in) diameter.&lt;/li>
&lt;li>Industrial‑grade glue or epoxy suitable for metal bonding.&lt;/li>
&lt;li>Cleaning materials (degreaser/isopropyl alcohol, lint‑free wipes).&lt;/li>
&lt;li>Personal protective equipment (PPE) as per site rules.&lt;/li>
&lt;/ul>
&lt;p>&lt;strong>Note&lt;/strong>: Magnets must not be used for long‑term retention and are not recommended for magnetic field measurements.&lt;/p>
&lt;p> &lt;/p>
&lt;h2 id="step-by-step-installation-guide">Step-by-step installation guide&lt;/h2>
&lt;p> &lt;/p>
&lt;h3 id="step-1-clean-the-surface">Step 1: Clean the surface&lt;/h3>
&lt;p>Clean the mounting surface on the asset thoroughly.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture3.png" width="200">
&lt;p> &lt;/p>
&lt;h3 id="step-2-attach-adapter-to-node">Step 2: Attach adapter to node&lt;/h3>
&lt;p>Take the Treon Magnetic Glue Mount Adapter for Curved Surface, place it on the Treon Industrial Node X. Carefully screw the adapter on to the node.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture1.png" width="150">
&lt;p>Tighten the connection with a spanner size 34 mm and a torque wrench to 20 Nm.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture2.png" width="200">
&lt;p> &lt;/p>
&lt;h3 id="step-3-apply-glue-to-surface">Step 3: Apply glue to surface&lt;/h3>
&lt;p>Choose an appropriate glue like the Loctite HY 4090. Follow closely the instructions that come with the glue!&lt;/p>
&lt;p>Apply the glue to the mounting area on the asset. The mounting area needs to be a minumum of 33 mm (1.30 in) in diameter.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture4.png" width="200">
&amp;nbsp;
&lt;h3 id="step-4-place-node-on-asset">Step 4: Place node on asset&lt;/h3>
&lt;p>Place the Treon Industrial Node X in the desired orientation on the area where you applied the glue. Make sure the magnet holds the node in place to secure the glue adhesion. Wait for the glue to dry.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/Picture5.png" width="200">
&amp;nbsp;
&lt;h3 id="verification">Verification&lt;/h3>
&lt;ul>
&lt;li>Confirm axis alignment marks match the intended directions.&lt;/li>
&lt;li>Run a quick measurement and validate expected directional sensitivity.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;p>&lt;strong>The Treon Industrial Node X is now fully installed!&lt;/strong>&lt;/p>
&lt;p> 
 &lt;/p>
&lt;h2 id="troubleshooting">Troubleshooting&lt;/h2>
&lt;details> &lt;summary>Error: The surface has paint.&lt;/summary>
If possible, remove all paint from the asset's surface. Make sure to consult the asset manufacturer's manual or contact the manufacturer directly if unsure.
&lt;/details>
&lt;details> &lt;summary>Error: The asset cannot be turned off.&lt;/summary>
In case the asset cannot be turned off for installation of the Treon Industrial Node X, please proceed with caution and take all safety protocols at the deployment site into account.
&lt;/details>
&lt;details> &lt;summary>Error: Glue does not dry or hold.&lt;/summary>
Choose an appropriate glue such as the Loctite HY 4090 and follow closely the instructions that come with the glue.
&lt;/details>
&lt;details> &lt;summary>Error: The asset was damaged.&lt;/summary>
If at any point it seems like the asset was damaged during the installation process, please consult the machine's repair manual or contact the manufacturer for further instructions on how to conduct the repair.
&lt;/details>
&amp;nbsp;
&amp;nbsp;
&lt;h2 id="disclaimer">Disclaimer&lt;/h2>
&lt;p>Treon is not responsible for any damage, injury, or malfunction resulting from the installation or use of the Treon Industrial Node X.&lt;/p>
&lt;p>Installation must be performed by qualified personnel.&lt;/p>
&lt;p>Any issues arising from incorrect installation, improper handling, or use outside the specified guidelines are the sole responsibility of the installer or end user.&lt;/p>
&lt;p> 
 &lt;/p></description></item><item><title>Installation with Direct glue mounting</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method5/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodex_mounting_method5/</guid><description>&lt;h2 id="introduction">Introduction&lt;/h2>
&lt;p>With the Direct Glue Mounting method, the Treon Industrial Node X is attached directly to the machine surface using glue. This provides the shortest possible vibration transmission path, delivering excellent measurement quality. Manual alignment of the Industrial Node X is possible before the adhesive cures, allowing the sensor to be oriented correctly for the application.&lt;/p>
&lt;p>This installation method requires a completely flat and smooth surface with a minimum diameter of &lt;strong>31.7 mm (1.25 in)&lt;/strong>. It is ideal for situations where drilling or tapping holes is not feasible. For best results, the node should be pressed firmly onto the surface until the glue or epoxy cures.&lt;/p>
&lt;p>&lt;strong>Applies to:&lt;/strong> Treon Industrial Node X&lt;br>
&lt;strong>Adapter:&lt;/strong> None (direct bonding)&lt;br>
&lt;strong>Use when:&lt;/strong> The surface is flat and smooth, drilling is not possible, and optimal vibration performance is required.&lt;/p>
&lt;h2 id="specifications">Specifications&lt;/h2>
&lt;table>
&lt;thead>
&lt;tr>
&lt;th>&lt;strong>Parameter&lt;/strong>&lt;/th>
&lt;th>&lt;strong>Value&lt;/strong>&lt;/th>
&lt;/tr>
&lt;/thead>
&lt;tbody>
&lt;tr>
&lt;td>Bonding&lt;/td>
&lt;td>Glue&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum mounting surface diameter&lt;/td>
&lt;td>31.7 mm (1.25 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Minimum thread hole depth&lt;/td>
&lt;td>–&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Total height (Node + adapter)&lt;/td>
&lt;td>80 mm (3.15 in)&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Curved surface&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Uneven surface&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Allows manual orientation&lt;/td>
&lt;td>Yes&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Frequency response (vibration)&lt;/td>
&lt;td>Excellent&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Temperature response (steady‑state)&lt;/td>
&lt;td>Excellent&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Fast temperature change response&lt;/td>
&lt;td>Excellent&lt;/td>
&lt;/tr>
&lt;tr>
&lt;td>Affects magnetometer measurements&lt;/td>
&lt;td>No&lt;/td>
&lt;/tr>
&lt;/tbody>
&lt;/table>
&lt;p> &lt;/p>
&lt;h2 id="requirements">Requirements&lt;/h2>
&lt;h2 id="requirements--direct-glue-mounting">Requirements – Direct Glue Mounting&lt;/h2>
&lt;p>For this installation method you will need:&lt;/p>
&lt;ul>
&lt;li>Treon Industrial Node X.&lt;/li>
&lt;li>Clean, flat mounting surface (minimum 31.7 mm / 1.25 in diameter).&lt;/li>
&lt;li>Industrial‑grade glue or epoxy (e.g., Loctite 4090 or equivalent).&lt;/li>
&lt;li>Cleaning materials (degreaser/isopropyl alcohol, lint‑free wipes).&lt;/li>
&lt;li>Clamps or fixtures to hold the node in position while adhesive cures (optional).&lt;/li>
&lt;li>Personal protective equipment (PPE) as per site rules.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;h3 id="step-1-clean-the-surface">Step 1: Clean the surface&lt;/h3>
&lt;p>Clean the machine surface thoroughly.&lt;/p>
&lt;h3 id="step-2-apply-glue">Step 2: Apply glue&lt;/h3>
&lt;p>Choose an appropriate glue like the Loctite HY 4090. Follow closely the instructions that come with the glue!&lt;/p>
&lt;p>Apply the glue to the mounting area on the asset. The mounting area needs to be a minumum of 31.7 mm (1.25 in) in diameter.&lt;/p>
&lt;p>&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_125925.jpg" width="300">&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_125939.jpg" width="300">&lt;/p>
&lt;p> &lt;/p>
&lt;h3 id="step-3-place-node-on-asset">Step 3: Place node on asset&lt;/h3>
&lt;p>Place the Treon Industrial Node X in the desired orientation on the area where you applied the glue. Hold it in place to secure glue adhesion.&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/installation/20251107_125949.jpg" width="300">
&amp;nbsp;
&lt;h3 id="verification">Verification&lt;/h3>
&lt;ul>
&lt;li>Confirm axis alignment marks match the intended directions.&lt;/li>
&lt;li>Run a quick measurement and validate expected directional sensitivity.&lt;/li>
&lt;/ul>
&lt;p> &lt;/p>
&lt;p>&lt;strong>The Treon Industrial Node X is now fully installed!&lt;/strong>&lt;/p>
&lt;p> 
 &lt;/p>
&lt;h2 id="troubleshooting">Troubleshooting&lt;/h2>
&lt;details> &lt;summary>Error: The surface has paint.&lt;/summary>
If possible, remove all paint from the asset's surface. Make sure to consult the asset manufacturer's manual or contact the manufacturer directly if unsure.
&lt;/details>
&lt;details> &lt;summary>Error: The asset cannot be turned off.&lt;/summary>
In case the asset cannot be turned off for installation of the Treon Industrial Node X, please proceed with caution and take all safety protocols at the deployment site into account.
&lt;/details>
&lt;details> &lt;summary>Error: Glue does not dry or hold.&lt;/summary>
Choose an appropriate glue such as the Loctite HY 4090 and follow closely the instructions that come with the glue.
&lt;/details>
&lt;details> &lt;summary>Error: The asset was damaged.&lt;/summary>
If at any point it seems like the asset was damaged during the installation process, please consult the machine's repair manual or contact the manufacturer for further instructions on how to conduct the repair.
&lt;/details>
&amp;nbsp;
&amp;nbsp;
&lt;h2 id="disclaimer">Disclaimer&lt;/h2>
&lt;p>Treon is not responsible for any damage, injury, or malfunction resulting from the installation or use of the Treon Industrial Node X.&lt;/p>
&lt;p>Installation must be performed by qualified personnel.&lt;/p>
&lt;p>Any issues arising from incorrect installation, improper handling, or use outside the specified guidelines are the sole responsibility of the installer or end user.&lt;/p>
&lt;p> 
 &lt;/p></description></item><item><title>Treon Industrial Node X activating</title><link>https://kb.treon.fi/industrialnodex/assetdeployment/nodexcommission/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://kb.treon.fi/industrialnodex/assetdeployment/nodexcommission/</guid><description>&lt;p>After installation, the Treon Industrial Node X needs to be turned on.&lt;/p>
&lt;p>Please note that we recommend first testing the Treon Gateway and all Treon Industrial Node X sensors before actual deployment. This way you make sure that all nodes connect to the gateway, and the gateway delivers data to your Treon Connect instance.&lt;/p>
&lt;p>This means that after deploying the Treon Industrial Node X sensors, they might already be turned on.&lt;/p>
&lt;h2 id="checking-the-node-status">Checking the node status&lt;/h2>
&lt;p>To check if the Treon Industrial Node X is turned on, follow these steps:&lt;/p>
&lt;ol>
&lt;li>
&lt;p>Press the power button briefly.&lt;/p>
&lt;/li>
&lt;li>
&lt;p>If the status light turns green, the sensor is connected.&lt;/p>
&lt;/li>
&lt;/ol>
&lt;p>CONNECTED
If the status light turns red, the sensor is not yet connected.&lt;/p>
&lt;p>NOT CONNECTED&lt;/p>
&lt;p>In case the sensor is not connected, the Gateway has been powered on, both sensor and Gateway are configured to same network and the sensor has had time to establish the connection, the sensor may be too far from the gateway or surroundings are blocking the radio connection. In either case, the gateway needs to be moved closer to the sensor or an additional routing sensor can be added between the sensor and the gateway to help routing the data.&lt;/p>
&lt;p> &lt;/p>
&lt;p>Please note that to press the button or view the led, the top cap of the sensor needs to be removed. You can also check if the sensor is connected to a Gateway by
 &lt;/p>
&lt;h2 id="activating-the-node">Activating the node&lt;/h2>
&lt;p>The Treon Industrial Node X can be powered on by two ways:&lt;/p>
&lt;p>a. Bring an NFC field (such as in a smartphone) to the proximity of the sensor.&lt;br>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_commission1.png" width="280">&lt;/p>
&lt;p>b. Press and hold the power button until the status light turns green.&lt;br>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_commission2.png" width="180">&lt;/p>
&lt;img src="https://kb.treon.fi/media/nodex/nodex_commission3.png" width="200">
&lt;img src="https://kb.treon.fi/media/nodex/nodex_commission4.png" width="200">
&lt;p> &lt;/p>
&lt;h2 id="deactivating-the-node">Deactivating the node&lt;/h2>
&lt;p>To switch off the Treon Industrial Node X, press the power button until the status light turns red, then let go of the button.&lt;/p>
&lt;p> &lt;/p>
&lt;p>The sensor serial number and a QR code including serial number are printed on the base of the sensor.&lt;/p>
&lt;p>You can also use an NFC reader, such as NFC-enabled mobile phone to read the identification number: switch on NFC on the reader and touch the left side of the of the sensor with the reader.&lt;/p></description></item></channel></rss>