Treon Industrial Node 6 Default Configuration

Treon Industrial Node 6

This article shows the default configuration of the Treon Industrial Node 6.

Fig.: Treon Industrial Node 6 DM Model.

 

Timer Parameters

TimeON/OFFMeasurement Selection
Timer 11hON0
Timer 26hON1
Timer 324hOFF2 and 3
Status Interval3hONnone

 

Measurement Parameters

Measurement ID0123Default
Axis333x-axisAll
G-Range44444
Sample Amount36864368643686468268110592
Calculations1 and 32 and 4560

 

Calculation Parameters

CalcID123456Default
Featuresv-RMS, v-PEAK, v-P2P, Clipping detectLOW FFT, Clipping detecta-RMS, a-PEAK, a-P2P, Kurtosis, Crest, Clipping detectHIGH FFT, Clipping detectRaw dataRaw dataFFT, aRMS, aPEAK
Low cut-off1010no filterno filterno filter
High cut-off10001333no filterno filterno filter
Decimation901
Averages090
Overlap %000
WindowHanningHanningHanning
Lines of resolution160016002048
FFT formatVariableVariableAuto (no variable)

 

Wakeup Parameters

Default
Feature EnableOFF
Wake-up G-range4G
Wake-up threshold8
Wake-up Action Delay30s
Wake-up Blank-time900s
Action measurementON
Action IndicationOFF
Action LEDON
Measurements to be triggered1