This article shows the default configuration of the Treon Asset Node.

ID Description Reporting Interval minutes Temperature Shock BT Beacon
Status Alert Alert Level Status
0 All Off OFF OFF OFF OFF OFF OFF
1 Test profile 5 Min set OFF ON OFF ON
2 Temperature monitoring 15 Full set OFF OFF OFF OFF
3 Temperature monitoring 60 Full set OFF OFF OFF OFF
4 Freezer monitoring 15 Full set < -31 or > -15 Min set in 5 min interval OFF OFF OFF
5 Freezer monitoring 60 Full set < -31 or > -15 Min set in 5 min interval OFF OFF OFF
6 Refrigerator monitoring 15 Full set < 0c or >8c Min set in 5 min interval OFF OFF OFF
7 Refrigerator monitoring 60 Full set < 0c or >8c Min set in 5 min interval OFF OFF OFF
8 Shock Monitoring (low) OFF OFF OFF ON >=15G OFF
9 Shock Monitoring (low) 30 Full set OFF ON >=15G OFF
10 Environmental and Shock monitoring 15 Full set OFF ON >=15G OFF
11 Environmental and Shock monitoring 60 Full set OFF ON >=15G OFF
12 Refrigerator and Shock monitoring 15 Full set < 0c or >8c Min set in 5 min interval ON >=15G OFF
13 Refrigerator and Shock monitoring 60 Full set < 0c or >8c Min set in 5 min interval ON >=15G OFF
14 Intrusion Alert 30 OFF OFF OFF OFF OFF
15 Shock Monitoring (high) OFF OFF OFF ON >=40G OFF
16 Shock Monitoring (high) 30 Full set OFF ON >=40G OFF
17 Rapid light 5 OFF OFF OFF OFF OFF
18 Refrigerator monitoring (meat and fish) 15 Full set < 0c or >4c Min set in 5 min interval OFF OFF OFF
19 Refrigerator monitoring (meat and fish) 60 Full set < 0c or >4c Min set in 5 min interval OFF OFF OFF

Notes: Full set = Current, Min, Max and Average values Min set = Current value Temperature measurement interval is 5 min