JSON Data Description for Treon Products

Legacy documentation

This page is preserved from the previous knowledge base and describes older Treon products and manual configuration workflows. It is kept for reference and is not maintained against current Treon Connect releases.

Article for advanced usersInformation on this page is intended for users with advanced technical knowledge.

JSON Data Description for Treon Products

Treon Industrial Node Treon Industrial Node 6 Treon Node Treon Asset Node

Introduction

Treon IoT-devices like the Treon Industrial Node, Treon Industrial Node 6, Treon Node and Treon Asset Sensor forward their measurements as binary data via the mesh network. The data is the processed by the Treon Gateway which then produces the JSON formatted data.

Legacy illustration

JSON Data

All Treon IoT-products contain a set of sensors which take readings depending on their individual specification and settings. The sensor data of these sensors is sent to the Treon Gateway through the mesh network. The Gateway then parses the messages and constructs a JSON message that is sent to a cloud backend. A JSON data dictionary structure contains values only from one IoT-device.

The contents of the JSON data depend on the configuration and the type of the IoT-device. JSON may also contain some additional key/value-pairs for development purposes. Any process using the JSON data can just ignore the keys it does not recognize.

Please note: Vibration data is only available from those Treon IoT-devices which are targeted for vibration analysis purposes.

JSON Message Types

Two main types of publish data exist: scalar values and stream data.

Scalar values are single readings or calculated values sent once from an IoT-device per measurement event.

Stream data contains array of data related to sampled measurement. Stream data is sent as a series of messages due to message size limitations of transfer technology.

The Treon Gateway with software releases from 6.2 onward may send also ‘diagnostic’ type JSON messages. These messages are not covered in this article.

Scalar Values JSON Formatting

Scalar-type messages are produced from all types of Treon IoT-devices. JSON message presents sensor values as key/value -pairs. Data type names (keys) start with capital letter.

****| JSON key | Notes | |---|---| | Acceleration | Single x,y,z acceleration value (JSON) in mG | | AirQuality | Air quality index, volatile organic compounds | | AirQualityStatic | Slowly changing AirQuality (more hysteresis) | | Ambient_light | Lightning (lux) | | BatteryAlert | Battery alert (boolean). Note: only true-value is sent. | | BatteryLevel | Battery level (%). | | BatteryVoltage | Battery voltage (mV) | | BurstDetails | Detailed information about burst that is starting (JSON) | | CO2Index | CO2 equivalent index | | DeviceType | Sensor device type (JSON) | | Distance | Distance reading | | GatewayId | Serial number of the gateway that sent the message. Number shown as HEX formatted string | | Hall | Magnetic hall switch (boolean) | | HwVer | Sensor HW version | | Humidity | Air humidity (%) | | IAQaccuracy | Air quality sensor calibration status | | IAQaccuracyStatic | IAQaccuracy for AirQualityStatic | | McuFw | Application MCU software version. | | MeasDetails | Details of the measurement (JSON) | | Movement | Movement detected (boolean): acceleration was larger than a predefined value | | NodeRole | Wirepas role of the sensor node | | NodeStatus | Status sent by the sensor node (bitmask) | | Objects | Object detected (boolean), PIR sensor | | Pressure | Air pressure (hPa) | | SelfTest | Selftest result bitmask (value 0 indicates that all tests are passed) | | SensorNodeId | IoT-device unique id as in the type label | | SourceAddress | Wirepas node address of the sensor node | | Temperature | Temperature (C) | | Timestamp | Unix epoch timestamp added by the gateway (seconds) | | Type | Message type (scalar/burst/diagnostic) | | User | User button (boolean) | | Vibration | Vibration data (JSON) | | Weight | Weight (g) | | WpFw | Wirepas stack software version |

Values for NodeRole
Value Notes
2 routing node
3 non-routing node
18 low-latency routing node
19 low-latency non-routing node
130 routing node, automatic role selection
131 non-routing node, automatic role selection
146 low-latency routing node, automatic role selection
147 low-latency non-routing node, automatic role selection

The value of HwVer varies inside a range. Treon can map these values for a specific hardware version.

Boolean values
Value Notes
0 false
1 true

JSON Fields

Acceleration contains information per axis:

Note: scalar-type acceleration data is not sent by Treon Industrial sensors. These sensors report acceleration raw data as burst data.

Parameter Notes
X Acceleration reading
Y Acceleration reading
Z Acceleration reading

The axis data is dependent on the IoT-device. Only data for some of the axis may be sent.

DeviceType contains the following information:

Parameter Notes
Class Sensor device class
Model Sensor device model

Scalar Values For Vibration data

Vibration data uses MeasDetails and BurstDetails parameters to report the calculated values and measurement parameters.

MeasDetails contain information about the current measurement event.

MeasDetails Data Types Notes
BinSize Frequency bin for FFT values (multiplied by 1000)
CalcId Calculation id
Fail Measurement failure (JSON)
FFT FFT details (JSON)
FftWindow Node’s internal FFT calculation parameter (enum)
FftSize Node’s internal FFT calculation parameter 512,1024,2048,4096
Filter Filtering details (JSON)
G-range G-range used in the measurement: 2G,4G,8G,16G
Id Measurement id
Precision Precision used in calculations (enum)
Trigger Measurement reason (bitmap)
ValueOffset Frequency Value offset for value array (multiplied by 10)

The measurement id range is either [0:255] or [0:65535] depending on the sensor type.

The calculation id is used in measurement data, like FFT burst, to reference the certain set of FFT and filtering parameters.

A measurement may contain multiple stream data elements based on the configuration of the Iot-device. Each stream data element is sent as a burst described by BurstDetails**:

BurstDetails Data Types Notes
MeasurementTimeInterval Sample time used to collect the samples (microseconds)
DataType Defines the type of data in the values array
ValueMapping Defines the semantics of the values contained in the Values array
BurstId Id used in each bust data fragment related to this data

The BurstId range is either [0:255] or [0:65535] depending on the sensor type.

Values for DataType:

Value Notes
2 Acceleration data
19 FFT coefficients

The format of the data is defined by ValueMapping.

Enum values for FftWindow:

FFT Window (enum) Notes
0 no window
1 hanning

Enum values for Precision:

Precision (enum)
0 float
1 fixed point Q15

Bitmap values for Trigger:

Trigger (bit) Notes
0 Timed measurement
1 Alert
2 Response to request
3 Timed measurement 2
4 Timed measurement 3

Information contained in FFT:

A separate FFT structure may be used instead of including FFT information into the body of MeasDetails. Reporting of FFT parameters depends on the sensor type and the software version.

Parameter Notes
BinSize Frequency bin for FFT values (multiplied by 1000)
CalcId Calculation id reference
FftWindow Node’s internal FFT calculation parameter (enum)
FftSize Node’s internal FFT calculation parameter 512,1024,2048,4096
Multiplier Multiplier for FFT coefficients
Overlap Sample overlap (%)
Precision Precision used in calculations (enum)
ValueOffset Frequency Value offset for value array (multiplied by 10)

Information contained in Filter:

Parameter Notes
CalcId Calculation id reference
Decimation decimation multiplier or 0 (no decimation)
HighCutoff Higher cutoff frequency (Hz), multiplied by 10
LowCutoff Lower cutoff frequency (Hz), multiplied by 10
Type Filter type: high pass(1),low pass(2), band pass (3)

The value is set to 0 if it is not applicable, like a higher cutoff frequency for a highpass filter.

Information contained in Fail:

Parameter Notes
CalcId Calculation id reference
MeasSetId Measurement set id reference
Reason Product specific failure code
Trigger Measurement trigger (enum)

Vibration data contains calculated scalar values for a measurement event:

Vibration Data Types Notes
Kurtosis Kurtosis (JSON)
V-P2P Velocity amplitude (JSON), mm/s
A-P2P Acceleration amplitude (JSON), m/s^2
V-RMS Velocity RMS (JSON), mm/s
A-RMS Acceleration RMS (JSON), m/s^2
V-Z2P Max zero-to-peak amplitude, mm/s
A-Z2P Max zero-to-peak acceleration, m/s^2
Crest Crest (JSON)
UsedRange Max %-value of range used in raw data (JSON)

On the JSON payload, all acceleration parameters have A- in front. Parameters without A- are velocity and not acceleration.

All vibration values are calculated from the same measurement event indicated by MeasId. The content of the JSON depends on the sensor configuration. E.g. if the sensor is configured to measure only the Y-axis, the RMS value is {“Y”: 34}.

NOTE: 6kHz Industrial Node: Acceleration, Velocity, Crest and Kurtosis values are coefficient values multiplied by 100. That means the values received in the backend must be divided by 100 again to reach the correct measurement value.

1kHz Industrial Node: Same as 6kHz BUT, Velocity Peak-to-Peak and Velocity Zero-to-Peak are NOT to be divided

Scalar Data Example

This is an example for scalar data. The calculated values from a Treon Industrial Node are: RMS, Kurtosis and amplitude.

\begin{Verbatim}[fontsize=\scriptsize]
{
  "SensorNodeId":"1bb9aebf",
  "SourceAddress":"12562103",
  "GatewayId":"bb3ff36a",
  "Temperature":23.67,
  "Timestamp":1631010967,
  "Vibration":
    {
      "RMS":
        {"Y":2,"X":2,"Z":2},
      "Kurtosis":{"Y":300,"X":311,"Z":296},
      "P2P":{"Y":11023,"X":16400,"Z":40130},
      "Z2P":{"Y":6096,"X":9346,"Z":25764}
    },
  "MeasDetails":
    {
      "FftSize":4096,
      "FftWindow":2,
      "G-range":4,
      "Precision":1,
      "BinSize":1000,
      "ValueOffset":0,
      "Trigger":1,
      "Id":200
    },
  "Type":"scalar"
}
\end{Verbatim}

The trigger value 1 (“Trigger”:1) indicates that the measurement was triggered by the measurement interval timer.

The measurement time interval is 181us, indicating a sample frequency of 1/181us = 5525Hz.

The frequency values from the values array are:

-

$$ n \in [0,values array length-1] $$

$$Frequency[n] = (ValueOffset/10) + (BinSize/1000)*n Hz $$

E.g.: The example frequency bin is (1000/1000) = 1 Hz. The FFT coefficients start from 0 Hz.

Stream Values JSON Formatting

Treon IoT-devices for vibration analysis like the Treon Industrial Node and Treon Industrial Node 6 send an array of sampled values or FFT coefficients as stream data. The data consists of several burst messages.

A Burst-type message contains:

JSON Names Notes
BurstId Burst identifier. Same for all JSON messages belonging to the same burst
BurstDataOffset Start offset of the values in the data array. Offset starts from 0
CalcId Calculation id used as reference to calculation parameters
DataSize Total amount of bytes in the complete burst i.e. same burst id
DataType Defines the type of data in the values array, e.g. acceleration
MeasurementId Measurement id associated with current measurement event
MeasurementTimeInterval Sample time used to collect the samples (microseconds)
SensorNodeId Sensor node serial number
Type “burst”. Indicates JSON containing burst data
Values Byte array containing the burst data
Val Values array as base64 encoded bytes
ValueMapping Defines the semantics of the values contained in the Values array

Scalar-type JSON containing BurstDetails has been send prior starting a burst.

If ValueMapping indicates compressed values, the Values-array must be processed by a decompression algorithm.

DataSize and BurstDataOffset values refer to compressed data.

The fields Values and Val are mutually exclusive, either one of them is present depending on the application configuration.

Example JSON messages for a burst data fragment. Default configuration using Values-field:

\begin{Verbatim}[fontsize=\scriptsize]
{
  "Type":"burst",
  "MeasurementId":63,
  "BurstId":141,
  "DataType":2,
  "ValueMapping":7,
  "MeasurementTimeInterval":149,
  "BurstDataOffset":24480,
  "DataSize":24576,
  "Values":[-46,31,-79,-1,17,0,24,32,-69,-1,-9,-1,49,32,-80,-1,-11,-1,19,32,-83,-1,5,0,16,32,-85,
    -1,3,0,11,32,-84,-1,-2,-1,32,32,-60,-1,7,0,22,32,-42,-1,8,0,0,32,-93,-1,7,0,-1,31,119,-1,-28,
    -1,-7,31,-91,-1,-40,-1,50,32,-111,-1,8,0,3,32,-107,-1,26,0,-12,31,-82,-1,14,0,23,32,-100,-1,
    32,0,8,32,-82,-1,14,0],
  "SensorNodeId":"dd0102c3",
  "GatewayId":"bb3ff36a"
}
\end{Verbatim}

Here following an alternative format which uses base64 encoded data for Values. Enabling this format requires a configuration change to the Treon Gateway. The field name is changed from Values to Val.

\begin{Verbatim}[fontsize=\scriptsize]
{
  "Type":"burst",
  "MeasurementId":59,
  "BurstId":137,
  "DataType":2,
  "ValueMapping":7,
  "MeasurementTimeInterval":149
  "BurstDataOffset":1536,
  "DataSize":24576,
  "Val":["+B/F//H/2B+o//j/2R+l//v/CCDK/xcADyC0/ycA8x+k/w0AIiCU/xEACyCT/wYA5h+O
    /wAA9h+F/wAA+h+2//3/DSDO/wEAGyDI/+r/CyCq/wUAECCk/+X/LyCh/+b/"],
  "SensorNodeId":"dd0102c3",
  "GatewayId":"bb3ff36a"
}
\end{Verbatim}

DataType: ‘2’ indicates that this is raw acceleration data.

ValueMapping: ‘7’ tells that Values or Val contains data sampled using 4G acceleration range and it should be read as signed 16 bit numbers.

MeasurementTimeInterval: ‘149’ tells the sampling interval in microseconds. The here used sampling frequency is 1/149 us = 6711 Hz.

Acceleration Data Burst

Indicated by DataType:2

ValueMapping Notes
4 Triplet of X,Y,Z acceleration 2G range [-128,127]
5 Triplet of X,Y,Z acceleration 4G range [-128,127]
6 Triplet of X,Y,Z acceleration 2G range [-32768,32767]
7 Triplet of X,Y,Z acceleration 4G range [-32768,32767]
8 Triplet of X,Y,Z acceleration 8G range [-32768,32767]
9 Triplet of X,Y,Z acceleration 16G range [-32768,32767]
10 X-axis [-32768,32767]
11 Y-axis [-32768,32767]
12 Z-axis [-32768,32767]
13 X-axis filtered and decimated values [-32768,32767]
14 Y-axis filtered and decimated values [-32768,32767]
15 Z-axis filtered and decimated values [-32768,32767]

For the ValueMaps 10-15 the G-range setting must be read from MeasDetails.

The Values array contains byte values as ‘signed’ bytes [-128,127].

If the number range is [-32768,32767], the values in the array are ordered as:

\begin{Verbatim}[fontsize=\scriptsize]
X[0]_LSB,X[0]_MSB, Y[0]_LSB,Y[0]_MSB,Z[0]_LSB,Z[0]_MSB,X[1]_LSB,X[1]_MSB, etc...
\end{Verbatim}

Acceleration data samples must be interpreted as signed integers (int16). Byte ordering is ‘little-endian’.

Here an example of pseudocode for decoding the Values array:

\begin{Verbatim}[frame=leftline,fontsize=\scriptsize]
  n = 0
  lsb_byte = Values[n]
  if lsb_byte < 0:
    lsb_byte = lsb_byte + 256
  n = 1
  msb_byte = Values[n]
  if msb_byte < 0:
    msb_byte = msb_byte + 256
  sample_reading = msb_byte*256 + lsb_byte
\end{Verbatim}

Please note that sample_reading must be interpreted as signed 16bit integer!

ValueMapping 4 indicates that Values array contains triplets of x,y,z acceleration data as int8 value using range -2G,2G. First acceleration value for X-axis is 15/127 * 2G = 0,236G

FFT Data Burst

Indicated by DataType:19

ValueMapping Notes Unit
0 FFT values from X-axis, uint16 Unit is mm/s
1 FFT values from Y-axis, uint16 Unit is mm/s
2 FFT values from Z-axis, uint16 Unit is mm/s
3 Delta compressed FFT values from X-axis, uint8 Unit is mm/s
4 Delta compressed FFT values from Y-axis, uint8 Unit is mm/s
5 Delta compressed FFT values from Z-axis, uint8 Unit is mm/s
6 FFT values from X-axis, uint16 Unit is m/s2
7 FFT values from Y-axis, uint16 Unit is m/s2
8 FFT values from Z-axis, uint16 Unit is m/s2
9 Delta compressed FFT values from X-axis, uint8 Unit is m/s2
10 Delta compressed FFT values from Y-axis, uint8 Unit is m/s2
11 Delta compressed FFT values from Z-axis, uint8 Unit is m/s2
12 FFT values from X-axis, uint16 Unit is m/s2. Multiplier from Measurement Details
13 FFT values from Y-axis, uint16 Unit is m/s2. Multiplier from Measurement Details
14 FFT values from Z-axis, uint16 Unit is m/s2. Multiplier from Measurement Details

By default, the Treon Industrial Node selects the output compression automatically if that produces less data. E.g. ValueMapping of consecutive x-axis FFT bursts may change between the values 0 and 3.

Values array contents must be read differently depending if delta compression is used or not:

-

No compression: Unsigned integer (uint16) numbers are read as ‘little-endian’ from Values array. It contains data only for one axis indicated by ValueMapping. Pseudocode is similar to the Acceleration Data example with the exception that sample_reading is interpreted as unsigned integer.

Compression: Refer to the next chapter ‘Compression’.

By default values are FFT coefficient values multiplied by 100, hence received values need to be divided by 100. FFT multiplier may be explicitly defined in MeasDetails.

Compression

Here an example for the FFT coefficient decompression:

\begin{Verbatim}[frame=leftline,fontsize=\scriptsize]
  i = 2
  n = 0

  Bytes = []
  for v in Values:
    if v < 0:
      v = 256 + v
    Bytes.append(v)

  #Initial value is always presented as 2 byte integer
  Coefficient[n] = Bytes[0] + 256*Bytes[1]
  n = n + 1
  while (i < len(Values)):
    # Small difference with consecutive values is handled as delta to the previous value
    if -127 < Values[i] < 127:
      Coefficient[n] = Coefficient[n-1] + Values[i]
      i = i + 1
      n = n + 1
    # value -128 is a marker byte used when difference is large. Coefficient is 2 byte integer
    elif Values[i] == -128:
      Coefficient[n] = Bytes[i+1] + 256*Bytes[i+2]
      i = i + 3
      n = n + 1
\end{Verbatim}

If e.g. consecutive values are shown as delta to the previous value as long as the abs(delta) is less than 128. Otherwise value -128 is a marker indicating that next two bytes must be decoded as little-endian integer (uint16).

Example: The received value array looks the like this:

\begin{Verbatim}
"Values": [52, 63, -128, 0, 0, 0, 0, 0, -128, -3, -123, -128, 85, 47,
56, -45, 0, 0,...
\end{Verbatim}

Interpretation:

  • The initial value is 16-bit unsigned integer, presented by little endian bytes 52 (0x34) and 63 (0x3F). This results first coefficient 0x3F34 = 16180 (base 10).
  • The next value ‘-128’ is a marker byte indicating that following two values in the array make up 16-bit unsigned integer: 0,0 -> 0
  • The next 3 values ‘0,0,0’ indicate the difference to the previous value -> next three coefficients are 0
  • The next value ‘-128’ is again a marker byte indicating that following two values form 16-bit unsigned integer: -3 (0xFD) -123 (0x85) -> 0x85FD = 34301 (base 10)
  • The next value'-128' is again a marker byte. The next coefficient is 85 (0x55), 47 (0x2F) -> 0x2F55 = 12117 (base 10)
  • Value 56 is the difference, so the next coefficient is: 12117 + 56 = 12173
  • Value -45 is the difference, so the next coefficient is: 12173 - 45 = 12128

Finally, all decompressed values have to be divided by 100 to get the original calculated coefficients.

Measurement Sequence

The measurement event for the Industrial Node sensors proceeds like this:

1.

Acceleration sensor is sampled for the period MeasurementTimeInterval. The temperature is also measured. The data is processed per each axis. The FFT axis data is sent when it is ready. Scalar values are aggregated for all requested axis prior sending scalar data. 1.

Burst Start message (with BurstId) is sent to the Gateway and MeasDetails is sent. The Gateway forwards these messages to the cloud backend. The scalar message with BurstDetails and MeasDetails is sent. 1.

FFT burst data is sent The Gateway forwards these messages to the cloud (BurstId is the same for all messages). The cloud backend decompresses the burst values data if needed. 1.

Repeat step 3 for all requested axes 1.

Scalar data with vibration values sent The Gateway forwards this message to the cloud backend.

Example Measurement

\begin{Verbatim}[frame=leftline,fontsize=\scriptsize]
{"Type":"scalar","Temperature":24.00,"GatewayId":"bb3ff36a","Timestamp":1605623123,"SensorNodeId":"d75eea0a",
  "BurstDetails":{"DataType":19,"MeasurementTimeInterval":152,"BurstId":69,"ValueMapping":5},
  "MeasDetails":{"FftSize":4096,"FftWindow":1,"G-range":4,"Precision":1,"BinSize":1000,"ValueOffset":0,
  "Trigger":1,"Id":16},
  "SourceAddress":"715359"}

{"FragCount":0,"ValueMapping":5,"DataType":19,"BurstId":69,"SensorNodeId":"d75eea0a",
  "Values":[9,0,-9,11,-1,-10,7,2,-9,6,-6,3,1,-4,3,-2,-1,1,-1,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
  0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0],
  "GatewayId":"bb3ff36a","BurstDataOffset":0,"DataSize":1002,"Type":"burst",
  "MeasurementId":16,"MeasurementTimeInterval":152}

{"FragCount":1,"ValueMapping":5,"DataType":19,"BurstId":69,"SensorNodeId":"d75eea0a",
  "Values":[0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
  0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0],
  "GatewayId":"bb3ff36a","BurstDataOffset":99,"DataSize":1002,"Type":"burst",
  "MeasurementId":16,"MeasurementTimeInterval":152}

... 8 more message fragments ...

{"FragCount":10,"ValueMapping":5,"DataType":19,"BurstId":69,"SensorNodeId":"d75eea0a",
  "Values":[0,0,0,0,0,0,0,0,0,0,0,0],
  "GatewayId":"bb3ff36a","BurstDataOffset":990,"DataSize":1002,"Type":"burst",
  "MeasurementId":16,"MeasurementTimeInterval":152}

{"SourceAddress":"715359","SensorNodeId":"d75eea0a","Timestamp":1605623127,"GatewayId":"bb3ff36a",
  "MeasDetails":{"Id":16},"Type":"scalar"}
\end{Verbatim}

Bluetooth Low Energy

When Bluetooth Low Energy parsing is enabled, the JSON data sent by the Treon Gateway can also contain data from the Bluetooth Low Energy sensors.

Additional JSON keys:

JSON key Notes
BtAdv Bluetooth advertising frame contents (base64 encoded).
BtRssi RSSI value reported by bluetooth.
SensorNodeId Bluetooth MAC address
iBeacon iBeacon data (JSON)
Eddystone Eddystone data (JSON)
TxPower Transmit power

iBeacon data:

JSON key Notes
UUID iBeacon unique ID
Major Major id
Minor Minor id

Eddystone data:

JSON key Notes
Frame Eddystone UID,URL
Namespace Eddystone UID
Instance Eddystone UID
Url Eddystone URL
AdvertisingCount Eddystone TLM
SecondsSinceBoot Eddystone TLM

Burst Fragments

Each burst will have a unique measurement id, e.g: "MeasurementId":225 and burst id e.g: "BurstId":133. (Ids are not completely unique but cycle from 0..n depending on the node.) You should identify your burst with this information along with SensorNodeId.

After you have your burst fragments you can start combining them into complete bursts with their "Values", "Valuemapping", "BurstDataOffset" and "DataSize"-fields where:

``````````````| Field | Meaning | |---|---| | "Values" | Contains byte-values from burst. Format will be specified by "Valuemapping". | | "Valuemapping" | Defines format of "Values"-field | | "BurstDataOffset" | Fragments starting bytes position in bytearray with size of "DataSize" | | "DataSize" | Size of the burst in bytes |

How bursts are split into fragments

Bursts are split into smaller fragments and sent via wirepas to gateway which sends them to cloud. Each fragment contains partial array of the data-bytes from the complete burst. Because these fragments cannot be guaranteed to come in correct order and some might be missing they have field "BurstDataOffset" which tells to whoever processes nodes messages that this bursts fragment starts at at this byte-offset.

Below figure should illustrate how burst offset works:

In addition to all of this data sent there is also field "FragCount" which should never be used when reconstructing the complete burst. Field "FragCount" is added by the gateway and is just incrementing counter of how many fragments have arrived to the gateway. This means that if a fragment with "BurstDataOffset" of 96 would come before fragment with "BurstDataOffset" of 0 it would get smaller "FragCount" than the fragment with offset of 0.