Skip to content

Installation with Direct Glue Mounting

Gives the shortest vibration path where there is no room for an adapter. The sensor cannot be removed afterwards, so use this method only when no adapter fits. You need a flat area at least 31.7 mm (1.25 in) across.

Prefer an adapter where there is room for one

Use this method only when an adapter cannot be used. An adapter lets the sensor be detached and attached again later; a sensor glued straight onto the surface cannot be removed that way. Glue the sensor directly only when there isn't enough space for an adapter.

The method needs a completely flat, smooth surface at least 31.7 mm (1.25 in) in diameter.

Use it when the surface is flat and smooth, drilling is not possible, and you need the best vibration performance.

Specifications

Parameter Value
Bonding Glue
Minimum mounting surface diameter 31.7 mm (1.25 in)
Minimum thread hole depth –
Total height (node only) 80 mm (3.15 in)
Curved surface No
Uneven surface No
Allows manual orientation Yes
Frequency response (vibration) Excellent
Temperature response (steady-state) Excellent
Fast temperature change response Excellent
Affects magnetometer measurements No

What you need

  • A Treon Industrial Node X.
  • A clean, flat mounting surface at least 31.7 mm (1.25 in) in diameter.
  • Industrial-grade glue or epoxy, such as Loctite 4090 or equivalent.
  • Cleaning materials: degreaser or isopropyl alcohol, lint-free wipes.
  • Clamps or fixtures to hold the node while the adhesive cures, if useful.
  • Personal protective equipment as per site rules.

No torque specification applies to this method, because there is no adapter joint to tighten.

Safety and preparation

  • Isolate or switch off the asset, and any equipment close to it, if your site procedures require it.
  • Choose a flat, smooth area larger than the sensor base, close to the measurement point and away from resonant or loose parts.
  • Clean the surface thoroughly. Remove paint, rust, oil and debris.

Step by step

1. Clean the surface

Clean the machine surface thoroughly.

2. Apply the glue

Choose a suitable glue, such as Loctite HY 4090, and follow its own instructions closely. Apply it to the mounting area on the asset. That area must be at least 31.7 mm (1.25 in) in diameter.

Applying glue to the mounting area

The glue applied, ready for the node

3. Place the node on the asset

Place the Treon Industrial Node X in the orientation you want, on the area where you applied the glue, and hold it there so the bond sets properly.

The node pressed onto the glued area

Verify

  • Confirm the axis alignment marks match the directions you intended.
  • Run a quick measurement and check the directional sensitivity is what you expect.

The Treon Industrial Node X is now installed.

Disclaimer

Treon is not responsible for any damage, injury, or malfunction resulting from the installation or use of the Treon Industrial Node X. Installation must be performed by qualified personnel. Any issues arising from incorrect installation, improper handling, or use outside the specified guidelines are the sole responsibility of the installer or end user.